TürkçeEnglish Home Page  

HRF 3000 H2O2 Plasma Sterilizer
Hydrogen Peroxide Plasma Sterilizer (H2O2)



HRF 3000 is an active low temperature hydrogen peroxide gas sterilizer enables the user to sterilize humidity and heat sensitive medical and surgical products at a glance by vaporizing hydrogen peroxide (H2O2) solution along with plasma technology. Fast, accurate and practical product sterilization is at your fingertips.

HRF 3000 is cost effective solution partner for practitioners at CSSDs thanks to its adjustable H2O2 penetration selection at each cycle enables you to consume adequate sterility by volume of products placed in the chamber.

MAIN SPECIFICATIONS
  • Sterilize Humidity and Heat Sensitive Products At a Glanced
  • Negative Pressure Working Principle
  • Enhanced HRF Plasma Sterilization Technology
  • Low Temperature (37-55 Cº) Working Principle
  • Sterilize With H2O2 Vaporizing Technology
  • Durable Lifelong Stainless Steel Chassis 316L
  • Comfortable 7'' Full-Colored Touch Screen
  • Preconditioning, Sterilization, Plasma, Aeration in One Chamber
  • Single or Double Door Selections
  • One Touch Operating System
  • Easy to Use - Plug in and Run
  • Sterilize Unique Lumen Shape Rigid Endoscopes and Flexible Endoscopes
  • No Toxic Residue Left
  • No Construction/Extra Equipment Needed
  • Compatible with Tyvek® and Sterilization Wraps
  • 10-6 Sterility Assurance Level
  • Undertakes Personal and Environmental Safety
  • Thermal Printer
  • Assigned to Cope With Challenges – PCD Test Free
HRF 3000 Introduces You 3 Different Sterilization Programs
  1. Quick Cycle: 30 Minutes to sterilize your less load items.
  2. Long Cycle: 45 Minutes to sterilize your flexible and semi-rigid instruments
  3. Lumen Cycle: 60 Minutes to sterilize your rigid, inflexible lumen shaped materials.

Full Cycle 52

Full Cycle 52

Full Cycle 56

Full Cycle 56

Full Cycle 64

Full Cycle 64

HRF 3000 Sterilizes Your Items by Following Specified Stages

Heating Stage: Sufficient temperature is reached at this stage (37-55 C°).

Leakage Test Stage: After reaching the adequate vacuum degree, chamber is tested for any leakage failure.

Aeration Stage: Before introducing H2O2 sterility, air inside of the chamber is taken.

HRF Plasma Occurrence: Optional Front Plasma aims to dry moisture products.

Vaporizing H2O2: Sterility is being taken to vaporize.

Introducing H2O2: Sterilization is being initiated.

Sterilization Phase: Sterility penetrates to the materials

HRF Plasma Occurrence: To reinforce the power of sterility, HRF Plasma occurs and reaching any edge of the materials fulfilled.

Aeration Stage: System gets ready for the second sterilization process

Second Sterilization Stage: Vaporized H2O2 sterility is being taken into chamber and penetration launches.

HRF Plasma Occurrence: To reinforce the power of sterility, HRF Plasma occurs and reaching any edge of the materials fulfilled.

Aeration Stage: Final aeration to get rid of any moisture inside.

Sterilization Completed.

CHAMBER SELECTIONS
Model Chamber Volume (Lt.) Effective Volume (Lt.) Inner Dimensions (mm.) Outer Dimensions (mm.)
W D H W D H
S75 92 75 440 700 300 300 680 1750
S125 154 131 440 700 500 500 680 1750
S175 193 167 550 700 500 500 850 1820
PRODUCTS FOR STERILIZATION

HRF 3000 is able to sterilize the heat and moisture sensitive surgical, plastic, organic, electromechanical tools. Here is some of the examples as a reference

ENDOSCOPES

Rigid Endoscopes

  • Laryngoscope
  • Arthroscopes
  • Laparoscopes
  • Trocar Cannula
  • Trocar Sheaths
  • Resectoscope
  • Similar

Flexible Endoscopes

  • Bronchoscope
  • Ureteroscope
  • Hysteroscope
  • Cystoscope
  • Choledochoscope
  • Similar

DEVICES

  • Implants
  • Defibrillator Paddles
  • Electrocautery Instruments
  • Esophageal Dilators
  • Cryo-probes
  • Dopplers
  • Cranial Pressure Transducer Cables
  • Cranial Pressure Transducer Cables
  • Endoscopic Instruments

PRODUCTS

  • Fiberoptic Light Cables
  • Laser Hand pieces
  • Fibers Accessaries
  • Ophthalmic Lenses
  • Patient Lead Cable
  • Radiation Therapy Equipment
  • Surgical Power Equipment, Batteries, Power Drill
  • Ultrasound Probes
  • Video Cameras and Couplers
MAINTENANCE

Periodical maintenance should be done by the authorized person between 6-12 months. Teknomar Ltd provides the essential spare parts with semi-annual and annual kits. Please follow our announcements for technical trainings and product presentation submits on our website.




Warnings:

  • It is mandatory to enter valid information in * marked fields. The preferred entry is from the + marked fields.
  • If your country and province information is in the selection boxes, select it.